ISIF
ISIF = 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8
| Default: ISIF | = 0 | for IBRION = 0 (molecular dynamics) or LHFCALC = .TRUE.
|
| = 2 | else |
Description: Determines if the stress tensor is calculated and which ionic degrees of freedom are varied.
For ISIF[math]\displaystyle{ \ge }[/math]2, the stress tensor is calculated. It is defined as the negative of the derivative of the energy [math]\displaystyle{ E }[/math] with respect to the strain tensor [math]\displaystyle{ \eta_{ji} }[/math]:
- [math]\displaystyle{ \sigma_{ij} = - \frac{\delta E} {\delta \eta_{ji}} }[/math].
This might be different from other first principles codes. A positive in the diagonals means that the system is under compressive strain and wants to expand. A negative value implies that the system is under tensile strain and wants to reduce its volume. The stress tensor is symmetric [math]\displaystyle{ \sigma_{ij}=\sigma_{ji} }[/math], and, thus, it has six independent entries. The calculation of the stress tensor is relatively time-consuming, and, therefore, by default, it is switched off in some cases. The forces are always calculated.
Tip: You can get information about the stress at each ionic step using NWRITE = 0,1,2,3.
|
ISIF also determines which degrees of freedom (ionic positions, cell volume, and cell shape) of the structure are allowed to change.
ISIF calculate degrees-of-freedom forces stress tensor positions cell shape cell volume 0 yes no yes no no 1 yes trace only yes no no 2 yes yes yes no no 3 yes yes yes yes yes 4 yes yes yes yes no 5 yes yes no yes no 6 yes yes no yes yes 7 yes yes no no yes 8 yes yes yes no yes
- For
ISIF = 1, only the trace of the stress tensor is calculated. This means only the total pressure is correct and can be read off in the line:
external pressure = ... kB
- The individual components of the stress tensor are not reliable in this case and must be disregarded.
- Accuracy
Warning: The PAW basis for the electronic minimization is not adjusted when the structure is varied during a calculation.
- Therefore, carefully consider effects such as Pulay stress and choose generous settings for the electronic minimization. Generally, volume changes should be done only with an increased energy cutoff, e.g.,
ENCUT = 1.3×max(ENMAX), andPREC = High.
- To further control the ionic degrees of freedom that can vary during the calculation, set `Selective dynamics` in the POSCAR file.
ISIF = 8is only available as of VASP.6.4.1.
Related tags and articles
IBRION, structure optimization, Ensembles, NWRITE, Selective-dynamics mode of the POSCAR file, LATTICE_CONSTRAINTS