ISIF

From VASP Wiki
Revision as of 07:47, 24 October 2025 by Singraber (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

ISIF = 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 

Default: ISIF = 0 for IBRION = 0 (molecular dynamics) or LHFCALC = .TRUE.
= 2 else

Description: Determines if the stress tensor is calculated and which ionic degrees of freedom are varied.


For ISIF[math]\displaystyle{ \ge }[/math]2, the stress tensor is calculated. It is defined as the negative of the derivative of the energy [math]\displaystyle{ E }[/math] with respect to the strain tensor [math]\displaystyle{ \eta_{ji} }[/math]:

[math]\displaystyle{ \sigma_{ij} = - \frac{\delta E} {\delta \eta_{ji}} }[/math].

This might be different from other first principles codes. A positive in the diagonals means that the system is under compressive strain and wants to expand. A negative value implies that the system is under tensile strain and wants to reduce its volume. The stress tensor is symmetric [math]\displaystyle{ \sigma_{ij}=\sigma_{ji} }[/math], and, thus, it has six independent entries. The calculation of the stress tensor is relatively time-consuming, and, therefore, by default, it is switched off in some cases. The forces are always calculated.

Tip: You can get information about the stress at each ionic step using NWRITE = 0,1,2,3.

ISIF also determines which degrees of freedom (ionic positions, cell volume, and cell shape) of the structure are allowed to change.

ISIF calculate degrees-of-freedom
forces stress tensor positions cell shape cell volume
0 yes no yes no no
1 yes trace only yes no no
2 yes yes yes no no
3 yes yes yes yes yes
4 yes yes yes yes no
5 yes yes no yes no
6 yes yes no yes yes
7 yes yes no no yes
8 yes yes yes no yes
  • For ISIF = 1, only the trace of the stress tensor is calculated. This means only the total pressure is correct and can be read off in the line:
external pressure =      ... kB
The individual components of the stress tensor are not reliable in this case and must be disregarded.
  • Accuracy
Warning: The PAW basis for the electronic minimization is not adjusted when the structure is varied during a calculation.
Therefore, carefully consider effects such as Pulay stress and choose generous settings for the electronic minimization. Generally, volume changes should be done only with an increased energy cutoff, e.g., ENCUT = 1.3×max(ENMAX), and PREC = High.
  • To further control the ionic degrees of freedom that can vary during the calculation, set `Selective dynamics` in the POSCAR file.
  • ISIF = 8 is only available as of VASP.6.4.1.