{{TAG|NHC_NCHAINS}} sets the length of the chain for the [[ | {{TAG|NHC_NCHAINS}} sets the length of the chain for the [[Nosé-Hoover chain thermostat]]. Typically, this tag is set to a value between 1 and 5. The maximal allowed value is 20. | ||
In case {{TAG|NHC_NCHAINS}}=0, the thermostat is switched off and the underlying dynamics generate a [[NVE ensemble|microcanonical (NVE) ensemble]]. {{TAG|NHC_NCHAINS}}=1 corresponds to the [[ | In case {{TAG|NHC_NCHAINS}}=0, the thermostat is switched off and the underlying dynamics generate a [[NVE ensemble|microcanonical (NVE) ensemble]]. {{TAG|NHC_NCHAINS}}=1 corresponds to the [[Nosé-Hoover thermostat|standard Nosé-Hoover thermostat]]. | ||
== Related tags and articles == | == Related tags and articles == | ||
{{TAG|NHC_PERIOD}}, [[ | {{TAG|NHC_PERIOD}}, [[Nosé-Hoover chain thermostat]] | ||
---- | ---- | ||
[[Category:INCAR tag]][[Category:Thermostats]] | [[Category:INCAR tag]][[Category:Thermostats]] | ||
Latest revision as of 21:46, 17 October 2025
NHC_NCHAINS = [integer]
Default: NHC_NCHAINS = 0
Description: Length of the Nosé-Hoover chain.
NHC_NCHAINS sets the length of the chain for the Nosé-Hoover chain thermostat. Typically, this tag is set to a value between 1 and 5. The maximal allowed value is 20.
In case NHC_NCHAINS=0, the thermostat is switched off and the underlying dynamics generate a microcanonical (NVE) ensemble. NHC_NCHAINS=1 corresponds to the standard Nosé-Hoover thermostat.
Related tags and articles
NHC_PERIOD, Nosé-Hoover chain thermostat