LTHOMAS: Difference between revisions
No edit summary |
No edit summary |
||
| Line 11: | Line 11: | ||
*If {{TAG|LTHOMAS}}{{=}}.TRUE., then {{TAG|LHFCALC}}{{=}}.TRUE. is automatically set. | *If {{TAG|LTHOMAS}}{{=}}.TRUE., then {{TAG|LHFCALC}}{{=}}.TRUE. is automatically set. | ||
*If {{TAG|LTHOMAS}}{{=}}.TRUE., then {{TAG|AEXX}}{{=}}1 is automatically set, but {{TAG|AEXX}} can be set to another value.}} | *If {{TAG|LTHOMAS}}{{=}}.TRUE., then {{TAG|AEXX}}{{=}}1 is automatically set, but {{TAG|AEXX}} can be set to another value.}} | ||
{{NB|important|When {{TAG|AEXX}}{{=}}1 (the default for {{TAG|LTHOMAS}}{{=}}.TRUE.), the correlation <math>E_{\mathrm{c}}^{\mathrm{SL}}</math> is not included. However, it can be included by setting {{TAG|ALDAC}}{{=}}1.0 and {{TAG|AGGAC}}{{=}}1.0.}} | |||
Since VASP counts the semi-core states and ''d''-states as valence electrons, although these states do not contribute to the screening, the values reported by VASP are often not recommended. | Since VASP counts the semi-core states and ''d''-states as valence electrons, although these states do not contribute to the screening, the values reported by VASP are often not recommended. | ||
Revision as of 09:37, 21 October 2025
LTHOMAS = .TRUE. | .FALSE.
Default: LTHOMAS = .FALSE.
Description: LTHOMAS selects a decomposition of the exchange functional based on Thomas-Fermi exponential screening.
If LTHOMAS=.TRUE. the decomposition of the exchange operator (in a range-separated hybrid functional) into a short range and a long range part will be based on Thomas-Fermi exponential screening. The Thomas-Fermi screening length kTF is specified by means of the HFSCREEN tag.
For typical semiconductors, a Thomas-Fermi screening length [math]\displaystyle{ k_{\rm TF} }[/math] of about 1.8 Å-1 yields reasonable band gaps. In principle, however, the Thomas-Fermi screening length depends on the valence-electron density. VASP determines [math]\displaystyle{ k_{\rm TF} }[/math] from the number of valence electrons (read from the POTCAR file) and the volume (average density [math]\displaystyle{ \bar{n} }[/math]) and writes the corresponding value of [math]\displaystyle{ k_{\rm TF}=\sqrt{4k_{\rm F}/\pi} }[/math], where [math]\displaystyle{ k_{\rm F}=(3\pi^2\bar{n})^{1/3} }[/math] to the OUTCAR file (note that this value is only printed for information; it is not used during the calculation):
Thomas-Fermi vector in A = 2.00000
| Mind: |
| Important: When AEXX=1 (the default for LTHOMAS=.TRUE.), the correlation [math]\displaystyle{ E_{\mathrm{c}}^{\mathrm{SL}} }[/math] is not included. However, it can be included by setting ALDAC=1.0 and AGGAC=1.0. |
Since VASP counts the semi-core states and d-states as valence electrons, although these states do not contribute to the screening, the values reported by VASP are often not recommended.
Related tags and articles
LHFCALC, HFSCREEN, LRHFCALC, Thomas-Fermi screening, List of hybrid functionals, Hybrid functionals: formalism