LORBIT: Difference between revisions
No edit summary |
|||
Line 25: | Line 25: | ||
*1. Self-consistent calculation with symmetry switched on (ISYM=2) | *1. Self-consistent calculation with symmetry switched on (ISYM=2) | ||
*2. Recalculation of the partial charge density with symmetry switched off (ISYM=0) | *2. Recalculation of the partial charge density with symmetry switched off (ISYM=0) | ||
To avoid unnecessary large {{TAG|WAVECAR}} files it recommended to set {{TAG|LWAVE}}=.FALSE. in step 2. | To avoid unnecessary large {{TAG|WAVECAR}} files it recommended to set {{TAG|LWAVE}}=.FALSE. in step 2 | ||
If LORBIT is set the partial charge densities can be found in the {{TAGBL|OUTCAR}} | |||
total charge | |||
# of ion s p d tot | |||
------------------------------------------ | |||
1 1.514 0.000 0.000 1.514 | |||
2 0.123 0.345 0.000 0.468 | |||
Here the first column corresponds to the ion index <math>\alpha</math>, the s, p, d,... columns correspond to the partial charges for <math>l=0,1,2,\cdots</math> defined as | |||
<math>\rho_{\alpha l}=\frac{1}{N_{\bf k}} \sum_{n{\bf k}}f_{n{\bf k}} \sum_{m=-l}^{l}|\langle Y_{lm}^{\alpha}|\phi_{n\mathbf{k}}\rangle|^2 | |||
</math> | |||
The <math>\langle Y_{lm}^{\alpha}|\phi_{n\mathbf{k}}\rangle</math> are obtained from the projection of the (occupied) wavefunctions <math>|\phi_{n{\bf k}}\rangle</math> onto spherical harmonics that are non zero within spheres of a radius {{TAG|RWIGS}} centered at ion <math>\alpha</math> and | |||
the last column is the sum <math>\sum_{l}\rho_{\alpha l}</math>. | |||
Note that depending on the system an "f" column can be found as well. | |||
In case of collinear calculations ({{TAGBL|ISPIN}}=2) the magnetization densities are written to the {{TAGBL|OUTCAR}} | |||
magnetization (x) | |||
# of ion s p d tot | |||
------------------------------------------ | |||
1 0.000 0.000 0.000 0.000 | |||
2 0.000 0.245 0.000 0.245 | |||
Here the magnetization density (projection axis is the z-axis) is calculated from the difference in the up and down spin channel <math>m^{\alpha l}_z = \rho_{\alpha l}^{\uparrow}-\rho_{\alpha l}^{\downarrow} | |||
</math> | |||
In case of non-collinear calculations ({{TAGBL|LNONCOLLINEAR}}=.TRUE.) the lines after "total charge" correspond to the charge density differences in the diagonal of the density | |||
<math> | |||
\rho_{\alpha l} = | |||
</math> | |||
the lines after "magnetization (x)" correspond to the partial magnetization density projected onto the x direction and two additional entries "magnetization (y)", "magnetization (z)" are written for the y and z direction. | |||
== Related Tags and Sections == | == Related Tags and Sections == |
Revision as of 16:37, 8 January 2019
LORBIT = 0 | 1 | 2 | 5 | 10 | 11 | 12
Default: LORBIT = None
Description: LORBIT, together with an appropriate RWIGS, determines whether the PROCAR or PROOUT files are written.
LORBIT RWIGS tag files written 0 required DOSCAR and PROCAR 1 required DOSCAR and lm-decomposed PROCAR 2 required DOSCAR and lm-decomposed PROCAR + phase factors 5 required DOSCAR and PROOUT 10 ignored DOSCAR and PROCAR 11 ignored DOSCAR and lm-decomposed PROCAR 12 ignored DOSCAR and lm-decomposed PROCAR + phase factors
Remark:
For LORBIT = 11 and ISYM = 2 the partial charge densities are not correctly symmetrized and can result in different charges for symmetrically equivalent partial charge densities. This issue if fixed as of version >=6. For older versions of vasp a two-step procedure is recommended:
- 1. Self-consistent calculation with symmetry switched on (ISYM=2)
- 2. Recalculation of the partial charge density with symmetry switched off (ISYM=0)
To avoid unnecessary large WAVECAR files it recommended to set LWAVE=.FALSE. in step 2
If LORBIT is set the partial charge densities can be found in the OUTCAR
total charge # of ion s p d tot ------------------------------------------ 1 1.514 0.000 0.000 1.514 2 0.123 0.345 0.000 0.468
Here the first column corresponds to the ion index [math]\displaystyle{ \alpha }[/math], the s, p, d,... columns correspond to the partial charges for [math]\displaystyle{ l=0,1,2,\cdots }[/math] defined as
[math]\displaystyle{ \rho_{\alpha l}=\frac{1}{N_{\bf k}} \sum_{n{\bf k}}f_{n{\bf k}} \sum_{m=-l}^{l}|\langle Y_{lm}^{\alpha}|\phi_{n\mathbf{k}}\rangle|^2 }[/math]
The [math]\displaystyle{ \langle Y_{lm}^{\alpha}|\phi_{n\mathbf{k}}\rangle }[/math] are obtained from the projection of the (occupied) wavefunctions [math]\displaystyle{ |\phi_{n{\bf k}}\rangle }[/math] onto spherical harmonics that are non zero within spheres of a radius RWIGS centered at ion [math]\displaystyle{ \alpha }[/math] and the last column is the sum [math]\displaystyle{ \sum_{l}\rho_{\alpha l} }[/math].
Note that depending on the system an "f" column can be found as well.
In case of collinear calculations (ISPIN=2) the magnetization densities are written to the OUTCAR
magnetization (x) # of ion s p d tot ------------------------------------------ 1 0.000 0.000 0.000 0.000 2 0.000 0.245 0.000 0.245
Here the magnetization density (projection axis is the z-axis) is calculated from the difference in the up and down spin channel [math]\displaystyle{ m^{\alpha l}_z = \rho_{\alpha l}^{\uparrow}-\rho_{\alpha l}^{\downarrow} }[/math]
In case of non-collinear calculations (LNONCOLLINEAR=.TRUE.) the lines after "total charge" correspond to the charge density differences in the diagonal of the density [math]\displaystyle{ \rho_{\alpha l} = }[/math]
the lines after "magnetization (x)" correspond to the partial magnetization density projected onto the x direction and two additional entries "magnetization (y)", "magnetization (z)" are written for the y and z direction.