CSVR PERIOD: Difference between revisions
Appearance
No edit summary |
corrected wrong units of CSVR_PERIOD |
||
| Line 2: | Line 2: | ||
{{TAGDEF|CSVR_PERIOD|[real]|0}} | {{TAGDEF|CSVR_PERIOD|[real]|0}} | ||
Description: Time scale of the [[CSVR thermostat|CSVR thermostat]] in | Description: Time scale of the [[CSVR thermostat|CSVR thermostat]] in fs. | ||
---- | ---- | ||
Latest revision as of 14:27, 27 July 2026
CSVR_PERIOD = [real]
Default: CSVR_PERIOD = 0
Description: Time scale of the CSVR thermostat in fs.
CSVR_PERIOD sets the time scale ([math]\displaystyle{ \tau }[/math]) of the CSVR thermostat. It is expressed in terms of the number of MD steps and must be interpreted in combination with the time step set by POTIM. Typically, CSVR_PERIOD should take the values corresponding to 2-2000 fs, whereby the smaller the value, the more aggressive the thermostating. The special setting CSVR_PERIOD=0 generates the NVE ensemble.